MiCAM03-C35IR is an imaging system equipped with a large 35mm full-size CMOS sensor, which has a spatial resolution of 2,160×1,280 pixels.
MiCAM03-C35IR uses an ultra-high sensitive CMOS sensor which has large pixels, uses low noise technology, and has > 80% quantum efficiency. This makes it possible to image dim fluorescent samples at wide fields of view, which was previously difficult to detect with sufficient S/N ratios.
Main Features
- Wide field of view: 35mm full-size CMOS sensor (47.7 mm diagonal)
- Ultra-high sensitivity: large 19umx19um pixel size, high quantum efficiency (> 80%), and new technology to reduce noise
- High frame rate: 52.6fps at 2,160×1,280 pixels spatial resolution
- A commercially available fluorescent filter can be installed in the camera head
Applications
- Wide-field imaging with the use of positive-dF fluorescence/luminescence probes
- Fluorescence imaging of entire multi-well plates
MiCAM series camera comparison showing light intensity levels and maximum frame rates
MiCAM series cameras have always been used for capturing light intensity changes at high speeds from bright fluorescence samples, but it has been difficult to capture sufficient S/N ratios from dark fluorescent samples.
MiCAM03-C35 makes it possible to image low light levels from dark fluorescent samples, which was previously difficult to detect with sufficient S/N ratios.
Very large sensor: wide field of view and brighter imaging is possible
When imaging a wide field of view, it is necessary to use a low-magnification lens. In general, however, low magnification lenses also have low numerical apertures, and images appear dim.
C35IR camera head has a large sensor, and users can image large field of views even when using higher magnification lenses, in comparison to cameras having smaller sensors. As a result, brighter imaging is possible with C35IR at wide fields of view.
In combination with Brainvision’s fluorescence macroscope, it is possible to assemble a wide-field / high resolution / high S/N ratio fluorescence imaging system.
High sensitivity: large pixel size, high quantum efficiency, low noise technology
Large pixel size of 19umx19um, high quantum efficiency of 80% or higher, and new technology to reduce noise. It is possible to capture signals in very dark fluorescence levels with high S/N ratios.
High frame rate: 52.6fps at 2,160×1,280 pixels
Imaging Mode | Number of pixels (H x V) |
Active area size (mm) (H x V) |
Maximum frame rate (fps) |
Minimum Exposure time (ms) |
---|---|---|---|---|
High Resolution Imaging |
2,160 x 1,280 | 41.0 x 24.3 | 52.6 | 19.0 |
2,108 x 1,080 | 40.1 x 20.5 | 61.7 | 16.2 | |
High Speed Imaging (Partial readout) |
1,276 x 1,280 | 24.2 x 24.3 | 89.3 | 11.2 |
1,212 x 1,080 | 23.0 x 20.5 | 107.5 | 9.3 | |
1,212 x 720 | 23.0 x 13.7 | 153.8 | 6.5 | |
1,212 x 360 | 23.0 x 6.8 | 277.8 | 3.6 | |
2×2 Binning | 1,080 x 640 | 41.0 x 24.3 | 90.9 | 11.0 |
A commercially available fluorescent filter can be installed in the camera head
A commercially available fluorescent filter (diameter 50 mm) can be installed inside the camera mount. Users can capture fluorescence by connecting a camera lens directly to the camera head without using a fluorescence microscope.
Dimensions
Direct Data Saving and Long-Term Data Acquisition with USB3.0 High-Speed Data Transfer
New USB3.0 interface allows for significantly faster data transfer from processor to PC. It is now possible to save data directly to HDD or SSD, and long-term recording of several minutes up to a few hours can be achieved, regardless of the RAM capacity (Note that sampling rate, number of pixels, number of cameras used, and PC specifications, will affect the total recording time).
Turnkey System Ready for Immediate Use
The system consists of hardware/software specifically designed for high-speed fluorescence imaging, and the PC and monitor are included as standard equipment. Before use, calibration/setting/tuning is not necessary. The hardware connection is straightforward between components using cables, making it possible to acquire data immediately after setup.
Various I/O Connectors, and Improved Compatibility with External Devices
MiCAM03 processor has multiple input and output connections available. These universally standard I/O connections can be synchronized with image acquisition and external devices.
Synchronous Lighting Control of LED Light Source for Multi-Wavelength Excitation Imaging
In the case of imaging using multiple fluorescent probes with different excitation wavelengths or imaging using a two-wavelength excitation/single-wavelength fluorescent probe, it is necessary to synchronize the frame timing of the camera and the lighting timing of the light source.
This function is to output the lighting signal synchronized with each frame timing from MiCAM03 processor to two LED light sources. This makes it possible to easily synchronize the frame acquisition with MiCAM03-C35IR and LED lighting.
There are up to 2 channels of output. Preset patterns, in which signals are output alternately from each channel, are available. There is no need to set the lighting pattern using a commercially available pulse generator.
Moreover, since the pulse delay time and pulse width can be specified by software, it is possible to make detailed settings in accordance with the rise and fall times of the LED used.
two-wavelength excitation mode
Time Lapse Imaging (optional)
MiCAM03-C35IR can capture phenomenon that changes in a few minutes up to several hours, intermittently. Because illumination light is turned on only at the time of image acquisition, phototoxic effects to sample is minimized, and a stable baseline can be acquired.
Example of Time-lapse imaging
Acquisition/Analysis Software (BV Workbench)
BV Workbench is the image acquisition software that controls MiCAM03-C35IR imaging system. In addition to image acquisition and control of inputs and outputs of the imaging system, analysis functions including movie playback, wave display, filter functions, etc…are also included. BV Workbench has an intuitive user interface that is easily operated with the use of a mouse.
System | ||
---|---|---|
Name | Ultra-High Sensitivity, Wide-Field Imaging System MiCAM03-C35 |
Ultra-High Sensitivity, Wide-Field Imaging System MiCAM03-C35IR |
Model | MC03-C35 | MC03-C35IR |
Standard System Configuration |
Camera Head (1), Processor, Cables, PC, Monitor,Acquisition software, Analysis Software |
|
Supported OS | Windows 10 64bit | |
Camera Head | ||
Name | C35 camera | C35IR camera |
Model | MC-C35CAM | MC-C35IRCAM |
Image Sensor | CMOS | Active Area Size (H x V) | 41.04 mm x 24.32 mm |
Pixel Format (H x V) | 2,160 x 1,280 pixels (2.76M pixels) | |
Unit Pixel Size (H x V) | 19μm x 19μm | |
Shutter | Rolling shutter | |
Dark Noise | 2.2 e- @gain x16 | 3.4 e- @gain x16 |
Full-Well Capacity | 61,000 e- | 70,000 e- |
Lens mount | EF-Mount, C-Mount, Others | |
Interface | Special Cable | |
Dimension (WxHxD) | 103mm x 103mm x 76.5mm | |
Weight | 920g | |
Processor | ||
Name | MiCAM03 processor | |
Model | MC03-PRC | |
Camera Interface | 1 | |
Camera Port | 1 (1 of 2 ports is available for C35 camera) |
|
Slot for Optional Unit | – | |
Buffer Memory Inside Processor |
1GB | |
Analog Inputs for synchronous recording |
2ch | |
Output for Stimulation Pulse | 1ch | |
Input for external trigger signal | 1ch | |
Output for Lighting Control | 1ch | |
Input/Output for Frame Timing | 1ch | |
Output for Real Time Light Intensity Monitor |
– | |
Output for Light Intensity Control | – | |
Current Output | – | |
Output for Acquisition Status | – | |
Output for Trigger Wait Status | – | |
Digital I/O port | 1 (6 pins) | |
Trigger Mode | Software, TTL External Input, Analog External Input |
|
Data Transfer Mode | USB3.0 | |
Recording Mode | Temporary storage to PC RAM / Direct data saving to PC drive (SSD/HDD) |
|
Maximum Recordable Frame Number |
Dependent on camera used and image acquisition settings | |
Power Supply | AC100V-230V、50Hz/60Hz 150W | |
Fuse | T2A L 250V | |
Dimension | 300mm(W) x 260mm(D) x 60mm(H) | |
Weight | 2.6kg |