GCaMP

合計: 6

Fast scanning high optical invariant two-photon microscopy for monitoring a large neural network activity with cellular resolution.

Keisuke Ota, Yasuhiro Oisi, Takayuki Suzuki, Muneki Ikeda, Yoshiki Ito, Tsubasa Ito, Kenta Kobayashi, Midori Kobayashi, Maya Odagawa, Chie Matsubara, Yoshinori Kuroiwa, Masaru Horikoshi, Junya Matsushita, Hiroyuki Hioki, Masamichi Ohkura, Junichi Nakai, Masafumi Oizumi, Atsushi Miyawaki, Toru Aonishi, Takahiro Ode, Masanori Murayama  

bioRxiv 2020.07.14.201699.
MiCAM ULTIMA In Vivo genetically encoded calcium indicator


Astrocytes Modulate Baroreflex Sensitivity at the Level of the Nucleus of the Solitary Tract.

Svetlana Mastitskaya, Egor Turovsky, Nephtali Marina, Shefeeq M. Theparambil, Anna Hadjihambi, Sergey Kasparov, Anja G. Teschemacher, Andrew G. Ramage, Alexander V. Gourine and Patrick S. Hosford  

J Neurosci. 2020 Apr 8; 40(15): 3052–3062.
MiCAM02-HR In Vivo genetically encoded calcium indicator


Detecting mTBI by Learning Spatio-temporal Characteristics of Widefield Calcium Imaging Data Using Deep Learning.

Fatemeh Koochaki, Foroogh Shamsi, Laleh Najafizadeh  

2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC).
MiCAM ULTIMA In Vivo genetically encoded calcium indicator


Distinct Contributions of Whisker Sensory Cortex and Tongue-Jaw Motor Cortex in a Goal-Directed Sensorimotor Transformation.

Johannes M. Mayrhofer, Sami El-Boustani, Georgios Foustoukos, Matthieu Auffret, Keita Tamura, Carl C.H.Petersen  

Volume 103, Issue 6, 25 September 2019, Pages 1034-1043.e5
MiCAM ULTIMA In Vivo genetically encoded calcium indicator


Decoding cortical brain states from widefield calcium imaging data using visibility graph.

Li Zhu, Christian R. Lee, David J. Margolis and Laleh Najafizadeh  

Biomed Opt Express. 2018 Jul 1; 9(7): 3017–3036.
MiCAM ULTIMA In Vivo genetically encoded calcium indicator


Odor representations in the olfactory bulb evolve after the first breath and persist as an odor afterimage.

Michael Andrew Patterson, Samuel Lagier and Alan Carleton  

Proc Natl Acad Sci U S A. 2013 Aug 27;110(35):E3340-9. doi: 10.1073/pnas.1303873110. Epub 2013 Aug 5.
MiCAM ULTIMA In Vivo Calcium Sensitive Dye





FRET

合計: 2

Chronic imaging of cortical sensory map dynamics using a genetically encoded calcium indicator.

Matthias Minderer, Wenrui Liu, Lazar T. Sumanovski, Sebastian Kügler, Fritjof Helmchen and David J. Margolis  [Author’s HP]

J Physiol. 2012 Jan 1;590(Pt 1):99-107.
MiCAM ULTIMA Dual Camera System In Vivo


Expanded dynamic range of fluorescent indicators for Ca(2+) by circularly permuted yellow fluorescent proteins.

Takeharu Nagai, Shuichi Yamada, Takashi Tominaga, Michinori Ichikawa and Atsushi Miyawaki

Proc Natl Acad Sci U S A. 2004 Jul 20;101(29):10554-9.
MiCAM01 Brain Slice




GEVI (Genetically Encoded Voltage Indicator)

合計: 3

Adaptive Behavior and the Role of Primary Somatosensory Cortex.

Christian Waiblinger, Peter Y Borden, Garrett B Stanley  

bioRxiv 2021.01.29.428886
MiCAM05-N256 In Vivo genetically encoded calcium indicator


Genetically expressed voltage sensor ArcLight for imaging large scale cortical activity in the anesthetized and awake mouse.

Peter Y. Borden, Alex D. Ortiz, Christian Waiblinger, Audrey J. Sederberg, Arthur E. Morrissette, Craig R. Forest, Dieter Jaeger, and Garrett B. Stanley  

Neurophotonics. 2017 Jul; 4(3): 031212.
MiCAM02-HR In Vivo genetically encoded calcium indicator


Optical recordings of membrane potential using genetically targeted voltage-sensitive florescent proteins.

Thomas Knopfel, Kayo Tomita, Ranken Shimazaki and Rieko Sakai.

Science direct Methods Volume 30, Issue 1 , May 2003, Pages 42-48
MiCAM01 genetically encoded calcium indicator


マクロ蛍光顕微鏡 THTシリーズ

THTシリーズは、生物サンプルから発せられる微弱な蛍光を低倍率で且つ極めて明るく観察できるマクロ蛍光顕微鏡です。

膜電位感受性色素を用いた膜電位イメージングのほか、GCaMP, FRETなど各種蛍光タンパク質を用いた広視野イメージング用として世界中の研究室で使用されおり、これまでよりもS/N比の良い画像データが得られると大好評です。

2本の大口径対物レンズと特注大型蛍光フィルターを組み合わせた非常にシンプルな光路で、わずかな蛍光量もロスなく検出できる設計になっています。2波長/3波長の同時計測セットアップや、実験条件・スペースに合わせたスタンドの変更/改造、その他ご要望に応じた特注品にも柔軟に対応可能です。